Air compressor exhaust high temperature is a frequent failure in the use of air compressors, resulting in a variety of reasons.

1. The ambient temperature is too high, causing the wind entering the radiator to be insufficient to cool the lubricant. This allows the machine to vent high temperatures.

Treatment measures: air compressor room ventilation treatment, so that the ambient temperature is maintained within the range of 5-35 degrees.

2. The front filter is clogged, causing cold air to enter the machine and causing the machine to vent high temperatures.

Remedy: Clean or replace the pre-filter.

3. The cooling fan is turned incorrectly or not turned, resulting in failure to cool the oil and the machine is venting at a high temperature.

Remedy: If the steering is wrong, the fan wiring is adjusted to make the direction correct. If not, check the power supply, contactor, fan, thermal protector and other components.

Summary

The high temperature failure of the air compressor exhaust can not be underestimated, directly affecting the operating cost and safety of the air compressor. When the temperature is high, the service life of the oil will be short, the oil content of the air will increase, the power consumption will increase, and the gas production will become smaller. If there is a fault, it needs to be resolved as soon as possible. In this way, the service life of the air compressor can be effectively extended and safe production can be achieved.