When the air compressor is running, it will generate a lot of heat. Usually, this heat needs to be discharged to the outside to avoid the air pressure room temperature is too high, exceeding the specified normal industrial environment temperature, that is, the maximum temperature is not higher than 40 ° C, keep The normal ambient temperature of the air compressor room has the following methods:
1. If the power of the unit is not large and the equipment room is relatively spacious, consider installing an exhaust fan directly at the height of the machine room wall and directly discharging the hot air in the equipment room to the outside.
2. If the power of the unit is large, the hot air can be taken out to the outside by the air duct. The cross section of the air duct should be the same as the air vent of the air compressor itself, and the entire air passage cannot be contracted from head to tail. , to ensure the proper curvature.
3. If the length of the air duct exceeds 5m, or the temperature of the air compressor room after the air duct is still too high, it is necessary to install an exhaust fan at the outlet of the air duct to enhance the air compressor ventilation. The exhaust air volume of the selected fan can be as follows. Equation a) or b) is calculated:
a) Ventilation of air-cooled air compressor: Qv =0.92 N/dT m3/s
b) Ventilation of water-cooled air compressor: Qv = 0.1N/dT m3/s
Remarks: In the above two formulas: Qv = required ventilation for the unit m3/s N = shaft power of the compressor in KW dT = temperature rise of the air compressor room, generally 8 °C
About Elang:
Product Recommendation:
-
Working pressure: 7~13bar 100~190psig Air delivery: 2.5~102m3/min 88~3600cfm Working power: 22~560kw 30~750hpdirect driven
-
Working pressure: 7~13bar 100~190psig Air delivery: 0.7~3.8m3/min 25~134cfm Working power: 7.5~22kw 10~30hpcombined
-
Working pressure: 6.5~13bar 95~190psig Air delivery: 0.5~102.0m3/min 17.7~3600cfm Working power: 5.5~560kw 7.5~750hp Frequency range: 40%~100%VSD
-
Working pressure: 6.5~13bar 95~190psig Air delivery: 0.5~102.0m3/min 17.7~3600cfm Working power: 5.5~560kw 7.5~750hp Frequency range: 40%~100%PM
-
Working pressure: 4.0~13bar 58~189psig Air delivery: 9.5~61.9m3/min 335.5~2189cfm Working power: 55~315kw 75~420hptwo-stage
-
Working pressure: 7~35bar 100~508psig Air delivery: 5.0~37.0m3/min 177~1310cfm Working power: 37~447kw 50~600hpportable
Company News:
-
Wating to meet you in HANNOVER
Date: Apr 4, 2019
-
Why choose us
Date: Apr 19, 2019
-
Global Recruitment Agency
Date: Jul 19, 2019
-
PTC Asia Invitation
Date: Jul 25, 2019
-
How to Choose the Location of the Air Compressor Room?
Date: Aug 19, 2019
-
How to Arrange an Air Compressor Room?
Date: Sep 4, 2019
-
What are The Precautions for The Connecting Pipe of The Air Compressor?
Date: Sep 16, 2019
-
What are The Requirements for Water-Cooling Air Compressors?
Date: Oct 15, 2019