Ten Common Senses of Frequency Converter Protection for Motors
As we all know, frequency converter adjusts the voltage and frequency of the output power through the interruption of internal IGBT, and provides with the required power supply voltage according to the actual needs of the motor, thereby achieving the purpose of energy saving and speed regulation. What are the ways and measures for the frequency converter to protect the motor? Let's take a look at it together!
-
1. Over-voltage Protection
The output of the frequency converter has a voltage detection function. It can automatically adjust the output voltage so that the motor does not bear over-voltage and the motor could run within the set voltage range.
-
2. Under-voltage Protection
When the voltage of the motor is lower than 90% of the normal voltage (some set to 85%), the frequency converter protects and stops.
-
3. Over current Protection
When the current of the motor exceeds 150% of the rated value for 3 seconds, or 200% of the rated current for 10 microseconds, the frequency converter protects the motor by stopping.
-
4. Open-phase Protection
When the output is lacking a phase., the frequency converter will alarm, and the frequency converter will stop immediately to protect the motor.
-
5. Phase-reversal Protection
The frequency converter can be set it that the motor can only rotate in one direction, and the rotation direction cannot be set. Unless the user changes the phase sequence of the wiring of the motor A, B and C, there is no possibility of inverting the phase.
-
6. Overload Protection
The frequency converter monitors the motor current. When the motor current exceeds 120% / 1 minute of the set rated current, the frequency converter will stop to protect the motor.
-
7. Ground Protection
The frequency converter is equipped with special ground protection circuit, which is generally composed of ground protection transformer and relay. When one or two phases are connected to the ground, the frequency converter will stop immediately. Of course, if the user requires, we can also be designed for immediate safety protection after grounding.
-
8. Short-circuit Protection
After the output of the frequency converter is short-circuited, it will inevitably cause over currency. The frequency converter will protect the motor by stopping within 10 microseconds.
-
9. Overclocking Protection
The frequency converter has the maximum and minimum frequency limit function, so that the output frequency can only be within the specified range, thereby realizing overclocking protection function.
-
10. Stalling Protection
Stall protection is generally aimed at synchronous motors. For asynchronous motors, the stall during acceleration must be manifested as over currency. The frequency converter realizes this protection function through over currency and overload protection. Stall during deceleration can be avoided by setting a safe deceleration time during commissioning.
About Elang:
Product Recommendation:
-
Working pressure: 7~13bar 100~190psig Air delivery: 2.5~102m3/min 88~3600cfm Working power: 22~560kw 30~750hpdirect driven
-
Working pressure: 7~13bar 100~190psig Air delivery: 0.7~3.8m3/min 25~134cfm Working power: 7.5~22kw 10~30hpcombined
-
Working pressure: 6.5~13bar 95~190psig Air delivery: 0.5~102.0m3/min 17.7~3600cfm Working power: 5.5~560kw 7.5~750hp Frequency range: 40%~100%VSD
-
Working pressure: 6.5~13bar 95~190psig Air delivery: 0.5~102.0m3/min 17.7~3600cfm Working power: 5.5~560kw 7.5~750hp Frequency range: 40%~100%PM
-
Working pressure: 4.0~13bar 58~189psig Air delivery: 9.5~61.9m3/min 335.5~2189cfm Working power: 55~315kw 75~420hptwo-stage
-
Working pressure: 7~35bar 100~508psig Air delivery: 5.0~37.0m3/min 177~1310cfm Working power: 37~447kw 50~600hpportable
Company News:
-
Wating to meet you in HANNOVER
Date: Apr 4, 2019
-
Why choose us
Date: Apr 19, 2019
-
Global Recruitment Agency
Date: Jul 19, 2019
-
PTC Asia Invitation
Date: Jul 25, 2019
-
How to Choose the Location of the Air Compressor Room?
Date: Aug 19, 2019
-
How to Arrange an Air Compressor Room?
Date: Sep 4, 2019
-
What are The Precautions for The Connecting Pipe of The Air Compressor?
Date: Sep 16, 2019
-
What are The Requirements for Water-Cooling Air Compressors?
Date: Oct 15, 2019
-
How to Ventilate the Air Compressor Room?
Date: Oct 29, 2019
-
What are The precautions for Installing The Main Circuit Cable of The Air Compressor?
Date: Nov 27, 2019
-
Analysis of Gumming and Carbon Deposit in Screw Air Compressor
Date: Dec 9, 2019
-
Advantages of Elang Oil Free Screw Air Compressor
Date: Dec 16, 2019
-
14 Tips for Compressor Operation
Date: Feb 14, 2020
-
ELANG 200kw Two-stage PM VSD Compressor Loading Flat Rack Container
Date: Mar 3, 2020
-
Why does Two-stage Screw Air Compressor Energy Saving?
Date: May 19, 2020
-
Elang Oil-free Air Compressor for Korean Instant Noodle Factory
Date: May 27, 2020
-
30m3/min 25bar Diesel Portable Compressor Delivery
Date: Jun 1, 2020